POCUS Pearls # 1

Primary Author: Dr Hywel James, Co-authors: Dr Gareth Hughes and Dr Alastair Robertson

 

The Foundations

Suboptimal image? Start here.

This is an aide-memoire, not a textbook. Find the correct module, look at the required image set.

With POCUS Pearls; Scan the Fix it list, check the Tricks and Pitfalls, and go back to the patient


The 60-second rescue

  1. Depth first. Too deep wastes resolution. Bring the structure to the middle of the screen.

  2. Focus at or just below the target. Check if your machine uses auto-focus, if so identify optimal depth.

  3. Gain: adjust with the TGC sliders rather than cranking overall gain.

  4. Right probe. Curvilinear, phased array, or linear.

  5. Move the patient, not just the probe. Position, utilise breath-holding, and embrace gravity.

  6. Environment: optimise lighting and look to limit sunlight over the bedspace

 

Probes at a glance

  • Curvilinear: default for eFAST, Hydronephrosis and Gallbladders.

  • Phased array: for cardiac. Small footprint also allows access between ribs, pelvic binders, upper abdomen and suprapubic views.

  • Linear: default for soft tissue, pleura / pneumothorax and superficial vascular. Try for bowel peristalsis (limited depth).

Position at a glance

  • Optimise your position and machine settings: ergonomics are key for image optimisation

  • Optimise patient position: open up an acoustic window, shift obstructive gas, bring the target closer.

  • Manipulate fluid: use gravity to help detect fluid shift; it will naturally pool in the lowest point of a body cavity.

 

7 habits for successful scanning

  • Use gravity. Left lateral brings the liver down for RUQ, hydronephrosis and gallbladder views. Also assists with cardiac views. Right lateral can open up splenic window.

  • Find the window. Large movement to find a window, fine movements to look through it.

  • Rib shadows: ask for a deep breath in, slide along the rib margin rather than across it, and rotate slightly oblique to look between ribs.

  • Bowel gas: apply graded, gradual compression and hold it so gas can shift. Rock and fan the probe rather than lifting and replacing. Use the liver or spleen as a window.

  • The timing trick: if a view is blocked by gas, move on and come back later. Gas often redistributes during the rest of the scan.

  • Sore patient: scan in the position they tolerate. Small probe movements and fanning can still give high quality images.

  • Don't interpret in real time. Concentrate on acquiring good images at the bedside, then interpret afterwards. Save short cine loops, especially for dynamic findings (bowel, lung sliding, free fluid). Stills for static measurements. Document using a POCUS proforma in EMR.

 

RECAP: The Fundamentals

* * * * *

RECAP: The Fundamentals * * * * *

Fix it

  • Depth first, then focus.

  • Adjust the Gain: TGC sliders.

  • Move the patient: left lateral for RUQ and kidney, right lateral for spleen.

  • Breath-hold at end inspiration for optimising liver, spleen, kidney, pleura and subcostal cardiac.

  • Bowel gas: graded steady pressure, rock and fan, or move on and return later.